H03 VV-F - 300 V

Application

H03 VV-F is used as a supply line for utility items in accordance with SB section 6:2001 and as an internal wire in utility items/lighting items, etc., according to construction regulations.

Construction

Conductor

Finely stranded Cu according to DIN VDE 0295, class 5

Insulation

PVC TI2 according to DIN VDE 0207 part 4

Conductor color

According to DIN VDE 0293-308

Outer sheath

PVC TM2 according to DIN VDE 0207 part 5, black or white

Technical data

Working temperature
Flexible:

-5º C til +70º C

Fixed:

-40º C til +70º C

Rated voltage

300 V

Test voltage

2000 V

Bend radius

7.5 x cable diameter

Eca

Approvals

EN 50575, IEC 60332-1, VDE 0285-525-2-71, VDE 0285-525-2-11, CE, RoHS
Bending radius 7,5 x cable diameter
Can lay in tubes
Flame retardant acc. to IEC 60332-1
Flexible
For use in homes
Max. working temp. +70° C
Meter marked
Min. working temperature -40° C
Resistance towards oil and chemicals
Water resistant
SKU EAN CPR Dimension (mm2) Current Value (A) Winding Color Diameter (mm)* Weight (kg/km)*
- - Eca 2x0,50 - D./Cut Sort 5,0 36
801012 5704403018857 Eca 2x0,75 - R-100 Hvid 5,5 44
801012S 5704403018864 Eca 2x0,75 - R-100 Sort 5,5 44
801013 5704403018871 Eca 3G0,75 - R-100 Hvid 6,6 60
801013S 5704403018888 Eca 3G0,75 - R-100 Sort 6,6 60
801014 5704403027835 Eca 4G0,75 - R-100 Hvid 7,2 75
801014S 5704403018901 Eca 4G0,75 - R-100 Sort 7,2 75
801015 5704403031436 Eca 5G0,75 - R-100 Hvid 8,0 99
801015S 5704403051243 Eca 5G0,75 - T-500 Sort 8,0 99